Mechanical values and environment | |
---|---|
Number of safety outputs | 2 Static, self-monitoring PNP safety outputs With short circuit and overload protection |
Resolution | 40 mm |
Height of the protective field | 1210 mm |
Height of the sensor | 1263 mm |
Maximum length of connection cables | 100 m |
Range of the protective field | 12000 mm |
Dimensions | 28x30 mm In cross-section |
Ambient temperature | -30 ... 55 °C |
Degree of protection | IP 65 / IP 67 |
Installation position | Any Optional: adjustable holders |
Reaction time | 11,5 ms |
Connection | PИли отправьте нам запрос наansmitter / 8-pin receiver) |
Electrical connection ratings | |
Cascadable | No |
Muting possible | In combination with external sensors and an evaluation unit |
Operating voltage DC | 24 V DC -20% ... +20% |
Current consumption | 400 mA |
Power consumption | |
Transmitter | 1 W |
Receiver | 2 W |
LED indicator | Yes Self-diagnostics and status |
Reliability values acc. to EN ISO 13849-1 | |
ESPE type | 2 Acc. to EN 61496-1 |
Performance Level | PL c acc. to EN ISO 13849-1 |
PFHD | 5,05x10-8 |
Safety Integrity Level | SIL 1 / SILCL 1 According to IEC 61508-1...4 / IEC 62061 |
Mission time | 20 y |
8 (029) 555-8-000 | |
8 (044) 555-8-000 | |
8 (017) 255-8-000 |